All risers and all goings in the same flight of stairs shall be of uniform dimensions within a tolerance of 5 mm.
Commercial stair tread and riser requirements.
The ibc stair codes are slightly different than the ones set by the irc.
The stair tread code requirements are also slightly different with a minimum depth of 11 inches.
Minimum 6 8 headroom height clearance for stairway.
Risers the vertical element connecting treads that are no less than 6 inches in height and no more than 7 5 inches.
Vertical clearance above any stair tread to any overhead obstruction is at least 6 feet 8 inches 203 cm as measured from the leading edge of the tread.
Maximum 4 1 2 inch handrail projection into stairway width on either side.
Commercial stair riser height the code specifies that risers should not be more than 7 inches in height and not less than 4 inches when measured vertically between the nosing of the adjacent tread.
Stair riser heights shall be 7 inches 178 mm maximum and 4 inches 102 mm minimum.
Therefore let us recap on the residential stair code requirements.
For example the maximum stair riser height is 7 inches and minimum is 4 inches.
In short the width is.
Width and capacity ibc 1011 2 the number of occupants on each floor will determine the required width of the stairs.
This distance must be at least 10 inches.
Spiral stairs must meet the vertical clearance requirements in paragraph d 3 of this section.
International building code for stair treads and risers 1009 3 stair treads and risers.
Minimum 36 inch clear width for stairway.
Riser and tread dimensions should be continuously uniform for safety.
The tread depth is the distance from the front edge or nosing a tread projection that overhangs the riser below of one step to the front edge or nose of the next step measured horizontally.
The riser height shall be measured vertically between the leading edges of adjacent treads.
Treads the horizontal stair element you step on that are at least 10 inches in depth and no more than 14 inches.
In summary osha compliant fixed stairs must have.
Maximum 12 3 vertical height rise for a flight of stairs.
1910 25 b 3 stairs have uniform riser heights and tread depths between landings.
Ibc stairs code requirements.
Headroom ibc 1011 3 riser height and tread depth ibc 1011 5 uniform dimensions ibc 1011 5 4 solid risers ibc.
Risers goings and treads dimensions.
Building codes limit variation to 3 8 10 mm the underside of risers should be sloped or have a 60 angle minimum between nosings and the horizontal surface open risers are not allowed under ada guidelines.
The international building code sets the commercial building code for stairs.